top of page

Summary of Total Loads and Stresses

in Beams and Columns

 

Cross sectional area of column = 0.209 m2

 

Table 3: Column Loads and Stresses

The compressive resistance for Douglas fir is 49.9 MPa according to the NBCC so column failure is not a concern for this project.

 

Cross sectional area of beam = 0.0929 m2

Length of lateral beam = 1.37 m, Length of longitudinal beam = 1.83 m

Assuming max. bending moment is at midspan of each beam

 

Table 4: Beam Loads and Stresses

 

 

The bending resistance for Douglas fir is 85.0 MPa according to the NBCC. The most significant stress is in B8 but the safety factor is still greater than 2 so there is no concern there.

 

So we conclude that the floor extension is structurally feasible for the given location and area. However, we still suggest hiring a structural consultant to thoroughly check the feasibility.

bottom of page